5V, 12V, 24V Switching Power Supply

5V, 12V, 24V Switching Power Supply

5V, 12V, 24V Switching Power Supply is used to supply power to laser control card etc. Laser Machine Parts, this DC Switch Power Supply is very important laser accessories for Laser Cutting and Engraving Systems.

Protection: Over load, over voltage, short circuit

 

Model
  Specification

S-50-5

S-50-12

S-50-15

S-50-24

DC output voltage

5V

12V

15V

24V

Output voltage error (Note2)

± 2%

± 1%

± 1%

± 1%

Rated output current

10A

4.2A

3.4A

2.1A

Output current rage

0-10A

0-4.2A

0-3.4A

0-2.1A

Wave and noise(Note3)

75mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

± 0.5%

± 0.5%

± 0.5%

± 0.5%

Load stability(Note5)

± 1%

± 0.5%

± 0.5%

± 0.5%

DC output power

50W

50.4W

50.4W

50.4W

Efficiency

71%

78%

78%

82%

Adjustable range for DC voltage

± 10, -5%

± 10%

± 10%

± 10%

AC input voltage range

85∼ 132VAC/170∼ 264VACselected by switch

Input current

1.3A/115V 0.65A/230V

AC  impulse current

Cold-start current 18A/115V 36A/230V

Leakage current

< 0.5mA/240VAC

Overload protection


105%∼ 150%TypeTOLDBACK Reset: auto recovery

Over-voltage protection

 

High-temperature protection

 

Temperature coefficient

± 0.03%(0∼ 50)

Setup rise hold up time

200ms, 100ms, 30ms

Vibration

10∼ 500Hz, 2.10min. /1cycle, Period for 60min, Each axes

Withstand voltage


Input and output interval1.5KVAC, Input and enclosure1.5KVAC, Output and enclosure0.5KVAC

Isolation resistance

Input and output interval, Input and enclosure, Output and enclosure0500VAC/100M Ohms

Working temperature and humidity

-10∼ +60, 20%∼ 90%RH

Store temperature and humidity

-20∼ +85, 10%∼ 95RH

Overall dimension

159*97*38mm

Weight

0.5Kgs

Safety standards

Meet UL1012

EMC standards

 

Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25 70%Rh, Humidity
2. Error, include the setting error, line stability and load stability. (Note: 5)
3. Wave test: adoptingA12double wire for 20MHz, and 0.1uF& uF capacitor short-circuit for interrupting
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5. Load stability test: The load is from 0% to 100%, others 60%.
6. C2311must be knocked down.